AWD NVH Chassis Dynamometer Test Cell 2.0

Contact us for price

Location:Coventry, United Kingdom

Specifications

ConditionUsed
Stock Number758722
Test Cell ReferenceCell 2.0
Test Cell StatusEmpty (TBC)
Equipment SupplierPotentially: ABB (Dynamotive Ltd)
Equipment TypeEmpty (TBC)
Roll DiametersAWD NVH chassis dynamometer rolls: front Ø2.76479 m; rear Ø1.90986 m
Roll Width-Space-Width700 mm - 1,000 mm - 700 mm
Axle Load2,500 kg / 2WD axle
Test Cell Floor Aperture8 m x 8 m floor opening
Speed RangeConstant force 0-160 km/h; constant power 160-320 km/h; overload force 0-131.4 km/h; overload power 131.4-320 km/h
Continuous ForceConstant 4,500 N / corner; 9,000 N / axle; 14,063 N in AWD; overload 20,957 N in AWD (150% short-term overload for 30 s once every 300 s, limited by ISU/AFE)
Continuous PowerConstant front 203 kW / corner; constant rear 201 kW / corner; constant front 406 kW / axle; constant rear 402 kW / axle; constant 625 kW in AWD; overload 765 kW in AWD (150% short-term overload for 30 s once every 300 s, limited by ISU/AFE)
Roll Surface Finish MaterialTungsten-carbide, approx. 88% Wn and approx. 12% Co
Roll Surface RoughnessRa 8.89 ± 1.27 µm
Base InertiaFront axle 2,100 kg; rear axle 1,300 kg
Inertia Simulation RangeFront 2WD 1,050 kg to 3,000 kg; rear 2WD 650 kg to 3,000 kg; AWD 1,700 kg to 4,000 kg
Wheelbase Adjustment2.55 m to 3.4 m
Acoustic PerformanceTarget <55 dB(A) @ 100 km/h; NR18 41 dB(A) @ 20 km/h; NR20 46 dB(A) @ 60 km/h; NR33 55 dB(A) @ 100 km/h
Ambient Specification0 °C to +40 °C; 85% RH non-condensing; >1000 m ASL
Oswald AC PM Machines - Cooling Water FlowFront axle 25.0 L/min for +15 K rise, per machine; rear axle 18.0 L/min for +15 K rise, per machine; maximum cooling water inlet temperature +25 °C
Oswald AC PM Machines - Bearing TypeInsulated rolling element
Oswald AC PM Machines - Thermal Protection3 x PTC in windings +155 °C; 3 x PT100 in windings; 2 x PT100 in bearings; cooling water flow switch
Oswald AC PM Machines - NDE Encoder TypeSick 2,048 TTL quadrature optical
Rolls Speed NDE Encoder TypeSick 10,000 TTL quadrature optical
HBM Load Cell Model and Range‘U10M’ - 0 N to ±12.5 kN
Electrical Supply Service RequirementsLimited 625 kW total export: 975 Aac @ 400 Vac, 3 Ph, 50 Hz; ABB technical manual rating for ACS880-204-1330A-3 ISU is 1,332 Aac based upon full continuous (100%) rating
Supplied EquipmentAC PM machines; bedframes; rolls; acoustic roll enclosures; AC MultiDrive; and DSP real-time control system
Omitted Equipmentflooring support structure; fixed flooring; moving flooring; moving central access; in-cell floor boxes; rigid vehicle restraint system; resin replica road surface shells; Ipetronik DAS; and wireless tablet PC