2023 Mader Nitrogen system for laser applications incl. bundle, KomPact-N-20-HD-SKID

2023 Mader Nitrogen system for laser applications incl. bundle, KomPact-N-20-HD-SKID
Contact us for price
Location:Stuttgart, Germany
Description
Manufacturer: Mader
Model: Nitrogen system for laser applications incl. bundle, KomPact-N-20-HD-SKID
Year of Manufacture : 2023
Nitrogen flow rate: 6.0 (99.9999%) / 20 Nm³/h
Condition: Used
Technical data:
Base frame dimensions (L x W x H): 2200 x 2200 x 2235 mm
Noise level: 55 to max. 85 dB(A)
Plug & Play system mounted on base frame platform
High-pressure compressor and bundle separate
Maximum outlet pressure: 300 bar
Ambient conditions: +4 °C to +45 °C
Nitrogen purity 5.0 (99.999%)
Maximum purity 6.0 (99.9999%)
Nitrogen pressure dew point: down to -60 °C
Nitrogen temperature: 10 °C above ambient
Control and monitoring:
Large, user-friendly touch display
Display and monitoring of:
Nitrogen flow rate
Residual oxygen
Nitrogen purity
Inlet pressure
Outlet pressure
Inlet temperature
Data logging
Interfaces and signals:
4–20 mA signal on terminal strip
USB / Ethernet / RS232 interface
Functions:
Alarm if purity falls below set value
Adjustable purity levels
Adjustable shut-off pressures
Advantages:
Plug & Play system, ready for immediate operation
High efficiency, low-maintenance design
Hydrogen technology
Automatic mixing
Air factor 2.9 (1 Nm³ N₂ = 2.9 Nm³ compressed air)
Continuous measurement of nitrogen purity
Trend display and data storage
Remote control, monitoring and operation
Included components:
1x fine filter
2x finest filter
1x activated carbon adsorber
1x particle filter
1x nitrogen generator
1x nitrogen buffer tank
1x hydrogen system
1x water separator
1x refrigeration dryer
1x nitrogen storage tank
1x high-pressure compressor
1x electrical distribution cabinet
Media quality requirements:
Required compressed air volume: 97.5 Nm³/h
Ambient temperature: +5 °C to max. +40 °C
Compressed air temperature: +10 °C to max. +40 °C
Compressed air quality according to DIN ISO 8573-1:
Particles: Class 1
Water: Class 4
Residual oil: Class 1
Hydrogen consumption: 2 liters per 1 Nm³ N₂
Hydrogen quality: 99.9%
Find more here - https://www.ucymachines.com/
Contact us at - sales@ucymachines.com
Specifications
| Manufacturer | Mader |
| Model | Nitrogen system for laser applications incl. bundle, KomPact-N-20-HD-SKID |
| Year | 2023 |
| Condition | Used |